Breast lymphomas only account for approximately 0.15% of malignant breast carcinomas. Half of these are primary lymphomas, and the other half are metastatic to the breast. Ultrasound elastography has been proven to aid in the diagnosis of breast…

There are multiple factors that affect the shear wave speed in the assessment of liver stiffness. In this case report, we present a case of hemochromatosis that has elevated liver stiffness suggestive of significant fibrosis or cirrhosis; however on…

Primary angiosarcoma of the breast is a rare entity. In this case report, we present a case of primary angiosarcoma of the breast in a young woman who presents with her entire right breast enlarged without skin coloration change or signs of mastitis.…

To determine if a significant contralateral stenosis affects interpretation tables of the ipsilateral internal carotid artery's degree of stenosis in duplex Doppler ultrasound, the records of 307 patients with carotid duplex ultrasound studies with…

PURPOSE: The aims of this study were to evaluate if a dynamic automatic image optimization technique decreases examination time and number of keystrokes while maintaining or improving image quality and to determine if these variables vary with…

Contrast-enhanced ultrasonography (CEUS) is an imaging modality that shows promise in the detection and characterization of renal masses, as well as treatment through CEUS-guided percutaneous radiofrequency ablation. These techniques may be…

PURPOSE: The purpose of this study was to evaluate blindly breast ultrasound images corrected for the speed of sound in breast tissue compared with conventional images. MATERIALS AND METHODS: In this study, 409 images from 153 patients were obtained…

PURPOSE: To determine the sensitivity and specificity of a real-time elasticity imaging (EI) ultrasound (US) system in the characterization of breast lesions as benign or malignant. METHODS: A total of 208 patients with 251 lesions were scheduled to…

The incidence of metastases to the breast from nonbreast carcinoma is less than 1% of all breast cancers; of these, adenocarcinoma of the lung to breast is a small proportion (\textless0.1% of breast carcinomas). The imaging findings of a case of…

Objective Strain ratio (SR) is a semiquantitative parameter in differentiating benign from malignant tumors in breast ultrasound elastography. Currently, SR is computed manually and, thus, user dependent. The objective of this study was to evaluate…

Purpose: The objective of this study was to evaluate electronic beam steering to improve needle visualization. Methods: Various needles ranging from 27 to 12 gauge were evaluated with a modified CX50 (Philips Ultrasound, Bothell, Wash) using a 12-MHz…

Purpose: The objectives of the study were to evaluate the accuracy of the "bull's-eye" artifact of elasticity imaging (EI) in determining the benignity of cystic breast lesions and to determine the utility of such artifact in reducing the biopsy rate…

On October 24, 2017, in Chicago, the Society of Radiologists in Ultrasound convened a panel of specialists in contrast-enhanced ultrasound (CEUS) to arrive at a white paper regarding the use of CEUS in noncardiac applications in North America.…