Intrauterine Vacuum-Induced Hemorrhage-Control Device for Rapid Treatment of Postpartum Hemorrhage.

Title

Intrauterine Vacuum-Induced Hemorrhage-Control Device for Rapid Treatment of Postpartum Hemorrhage.

Creator

D'Alton ME; Rood KM; Smid MC; Simhan HN; Skupski DW; Subramaniam A; Gibson KS; Rosen T; Clark SM; Dudley D; Iqbal SN; Paglia MJ; Duzyj CM; Chien EK; Gibbins KJ; Wine KD; Bentum NA; Kominiarek MA; Tuuli MG; Goffman D

Publisher

Obstetrics and Gynecology

Date

2020
2020-09-09

Description

OBJECTIVE: To evaluate the effectiveness and safety of an intrauterine vacuum-induced hemorrhage-control device for postpartum hemorrhage treatment. METHODS: ptA multicenter, prospective, single-arm treatment study of a novel intrauterine device that uses low-level vacuum to induce uterine myometrial contraction to achieve control of abnormal postpartum uterine bleeding and postpartum hemorrhage was undertaken at 12 centers in the United States. The primary effectiveness endpoint was the proportion of participants in whom use of the intrauterine vacuum-induced hemorrhage-control device controlled abnormal bleeding without requiring escalating interventions. The primary safety endpoint was the incidence, severity, and seriousness of device-related adverse events. Secondary outcomes included time to bleeding control, rate of transfusion, and device usability scored by each investigator using the device. RESULTS: Of 107 participants enrolled with primary postpartum hemorrhage or abnormal postpartum uterine bleeding, 106 received any study treatment with the device connected to vacuum, and successful treatment was observed in 94% (100/106, 95% CI 88-98%) of these participants. In those 100 participants, definitive control of abnormal bleeding was reported in a median of 3 minutes (interquartile range 2.0-5.0) after connection to vacuum. Eight adverse events deemed possibly related to the device or procedure were reported, all of which were outlined as risks in the study and all of which resolved with treatment without serious clinical sequelae. Transfusion of 1-3 units of red blood cells was required in 35 participants, and five participants required 4 or more units of red blood cells. The majority of investigators reported the intrauterine vacuum-induced hemorrhage-control device as easy to use (98%) and would recommend it (97%). CONCLUSION: Intrauterine vacuum-induced hemorrhage control may provide a new rapid and effective treatment option for abnormal postpartum uterine bleeding or postpartum hemorrhage, with the potential to prevent severe maternal morbidity and mortality. FUNDING SOURCE: Alydia Health, Inc. CLINICAL TRIAL REGISTRATION: ClinicalTrials.gov, NCT02883673.

Rights

Article information provided for research and reference use only. All rights are retained by the journal listed under publisher and/or the creator(s).

Format

journalArticle

Search for Full-text

Users with a NEOMED Library login can search for full-text journal articles at the following url: https://libraryguides.neomed.edu/home

ISSN

1873-233X 0029-7844

Update Year & Number

Hospital List

Citation

D'Alton ME; Rood KM; Smid MC; Simhan HN; Skupski DW; Subramaniam A; Gibson KS; Rosen T; Clark SM; Dudley D; Iqbal SN; Paglia MJ; Duzyj CM; Chien EK; Gibbins KJ; Wine KD; Bentum NA; Kominiarek MA; Tuuli MG; Goffman D, “Intrauterine Vacuum-Induced Hemorrhage-Control Device for Rapid Treatment of Postpartum Hemorrhage.,” NEOMED Bibliography Database, accessed April 19, 2024, https://neomed.omeka.net/items/show/11435.