Sources of Error in Office Blood Pressure Measurement

Title

Sources of Error in Office Blood Pressure Measurement

Creator

Morcos Roy N; Carter Kimbroe J; Castro Frank; Koirala Sumira; Sharma Deepti; Syed Haroon

Publisher

Journal of the American Board of Family Medicine: JABFM

Date

2019
2019-10

Description

PURPOSES: To evaluate 2 commonly overlooked sources of error in measuring blood pressure (BP) in the office, improper patient positioning and frequency of terminal digit bias (TDB) using manual and automated (BP) devices. METHODS: BPs recorded by 3 nurses using manual and automated devices were analyzed for TDB. In the next part of the study, 294 patients were recruited and tested with each patient's BP measured twice in the table position and compared with BP measured in the chair position. To eliminate concern for position sequence, a randomized controlled trial was initially conducted. RESULTS: Significant TDB for the digit zero was identified in BPs measured by all nurses using a manual device. No such bias was identified for any nurse when measuring BP with an automated device. For the positional study, the randomized controlled study showed no significant sequencing effect therefore the sequence of table then chair BP measurements was adopted. Significant BP lowering was observed in 128 patients (42.7%) in the chair compared with the table position. Misclassification of prehypertension and hypertension would have occurred in 15.3% and 16% of patients, respectively, when BP was recorded in the table instead of the chair position. CONCLUSIONS: Significant TDB was identified for all nurses when using a manual but not an automated device. Patient positioning on the examination table resulted in elevations of systolic and diastolic BPs.

Subject

bias; Blood Pressure; end-digit preference; global burden; hypertension; Hypertension; mercury; Patient Positioning; Prehypertension; prevalence
October 2019 Update

Rights

Article information provided for research and reference use only. All rights are retained by the journal listed under publisher and/or the creator(s).

Search for Full-text

Users with a NEOMED Library login can search for full-text journal articles at the following url: https://libraryguides.neomed.edu/home

Pages

732-738

Issue

5

Volume

32

Citation

Morcos Roy N; Carter Kimbroe J; Castro Frank; Koirala Sumira; Sharma Deepti; Syed Haroon, “Sources of Error in Office Blood Pressure Measurement,” NEOMED Bibliography Database, accessed March 28, 2024, https://neomed.omeka.net/items/show/6563.